Skip to content

Acoustic & Electronics Mesh · IEEE 299 / MIL-STD-188-125

40 Mesh Faraday Cage Shielding Mesh Specifications

A small Faraday cage enclosure built from copper woven mesh panels with soldered seams, electronic devices inside

40 mesh denotes 40 wires per inch in each direction. For faraday cage shielding mesh the governing document is IEEE 299 / MIL-STD-188-125; the specification row, aperture-micron conversion and selection guidance for this count follow.

40 Mesh Specification Row (IEEE 299 / MIL-STD-188-125)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialRoll width (mm)
40-Mesh0.1800.45551Copper1000

40 Mesh to Micron & Aperture

Openings per inch40
Aperture (opening width)0.39 mm
Micron rating385 µm
Standard wire diameter0.25 mm
Open area36.8 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 40 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.325 mm0.310 mm310 µm23.8 %2.18 kg/m²
Standard wire0.250 mm0.385 mm385 µm36.8 %1.29 kg/m²
Fine wire0.188 mm0.448 mm448 µm49.7 %0.72 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 40 Mesh

The standard 40 mesh weave presents an open area of about 36.8%. At this count the mesh presents little flow resistance; selection is normally driven by particle retention and mechanical strength rather than pressure drop.

40 Mesh Cloth Weight

Standard 40 mesh stainless cloth weighs approximately 1.29 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 40 Mesh Faraday Cage Shielding Mesh

40 mesh faraday cage shielding mesh is commonly specified for general straining and sieving, paint and coating filtration, grease filters, insect screening, grain cleaning and pre-filtration ahead of fine media.

Plain, Twill or Dutch Weave at This Rating?

Plain square weave is the standard at this count: every opening is a true square of the stated aperture, retention is absolute for hard spherical particles, and the cloth is easy to clean.

When to Step Up or Down from 40 Mesh

Move to 50 mesh when particles are passing that must be retained; drop back to 30 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Faraday Cage Shielding Mesh Does

Building Faraday cages, RF-shielded rooms and EMP-protected enclosures from conductive woven metal mesh that blocks external radio-frequency fields while staying light, ventilated and see-through.

Fitting & Care

  • Solder or clamp every seam continuously; spot fixings leave slot-shaped leaks.
  • Seal doors and lids with conductive finger stock or gasket, and filter any cable that enters.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (IEEE 299 / MIL-STD-188-125)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialRoll width (mm)
16-Mesh0.2801.30867Copper1000
22-Mesh0.1151.04081Copper1000
30-Mesh0.2500.59750Galvanized steel1220
40-Mesh0.1800.45551Copper1000
60-Mesh0.1100.31355Tinned copper1000

Frequently Asked Questions

What is the best metal mesh for a Faraday cage?

Copper woven mesh around 16–60 mesh; galvanized steel mesh is a cheaper alternative.

Does the mesh hole size matter for a Faraday cage?

Yes — openings must be much smaller than the wavelength being blocked, so higher frequencies need finer mesh.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.