30 mesh denotes 30 wires per inch in each direction. For faraday cage shielding mesh the governing document is IEEE 299 / MIL-STD-188-125; the specification row, aperture-micron conversion and selection guidance for this count follow.

30 Mesh Specification Row (IEEE 299 / MIL-STD-188-125)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialRoll width (mm)
30-Mesh0.2500.59750Galvanized steel1220

30 Mesh to Micron & Aperture

Openings per inch30
Aperture (opening width)0.55 mm
Micron rating547 µm
Standard wire diameter0.3 mm
Open area41.6 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 30 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.390 mm0.457 mm457 µm29.1 %2.35 kg/m²
Standard wire0.300 mm0.547 mm547 µm41.7 %1.39 kg/m²
Fine wire0.225 mm0.622 mm622 µm53.9 %0.78 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 30 Mesh

The standard 30 mesh weave presents an open area of about 41.6%. At this count the mesh presents little flow resistance; selection is normally driven by particle retention and mechanical strength rather than pressure drop.

30 Mesh Cloth Weight

Standard 30 mesh stainless cloth weighs approximately 1.39 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 30 Mesh Faraday Cage Shielding Mesh

30 mesh faraday cage shielding mesh is commonly specified for general straining and sieving, paint and coating filtration, grease filters, insect screening, grain cleaning and pre-filtration ahead of fine media.

Plain, Twill or Dutch Weave at This Rating?

Plain square weave is the standard at this count: every opening is a true square of the stated aperture, retention is absolute for hard spherical particles, and the cloth is easy to clean.

When to Step Up or Down from 30 Mesh

Move to 40 mesh when particles are passing that must be retained; drop back to 20 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Faraday Cage Shielding Mesh Does

Building Faraday cages, RF-shielded rooms and EMP-protected enclosures from conductive woven metal mesh that blocks external radio-frequency fields while staying light, ventilated and see-through.

Fitting & Care

  • Solder or clamp every seam continuously; spot fixings leave slot-shaped leaks.
  • Seal doors and lids with conductive finger stock or gasket, and filter any cable that enters.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (IEEE 299 / MIL-STD-188-125)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialRoll width (mm)
16-Mesh0.2801.30867Copper1000
22-Mesh0.1151.04081Copper1000
30-Mesh0.2500.59750Galvanized steel1220
40-Mesh0.1800.45551Copper1000
60-Mesh0.1100.31355Tinned copper1000

Frequently Asked Questions

What is the best metal mesh for a Faraday cage?

Copper woven mesh around 16–60 mesh; galvanized steel mesh is a cheaper alternative.

Does the mesh hole size matter for a Faraday cage?

Yes — openings must be much smaller than the wavelength being blocked, so higher frequencies need finer mesh.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.