Skip to content

Woven Wire Mesh · ASTM E2016 / ISO 9044

200 Mesh Nickel Wire Mesh Specifications

A square sheet of silvery woven nickel wire mesh used as an electrolyzer electrode, held in a lab clamp over a beaker

200 mesh denotes 200 wires per inch in each direction. For nickel wire mesh the governing document is ASTM E2016 / ISO 9044; the specification row, aperture-micron conversion and selection guidance for this count follow.

200 Mesh Specification Row (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
200-Mesh0.0500.0777736.8Nickel 201 (N02201)

200 Mesh to Micron & Aperture

Openings per inch200
Aperture (opening width)0.074 mm
Micron rating74 µm
Standard wire diameter0.053 mm
Open area33.9 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 200 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.069 mm0.058 mm58 µm20.9 %0.49 kg/m²
Standard wire0.053 mm0.074 mm74 µm34.0 %0.29 kg/m²
Fine wire0.040 mm0.087 mm87 µm47.2 %0.16 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 200 Mesh

The standard 200 mesh weave presents an open area of about 33.9%. A common design rule is to keep the clean-mesh approach velocity low enough that initial pressure drop is negligible; the mesh then acts as the cake support.

200 Mesh Cloth Weight

Standard 200 mesh stainless cloth weighs approximately 0.29 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 200 Mesh Nickel Wire Mesh

200 mesh nickel wire mesh is commonly specified for liquid filtration and clarification, extruder screen packs, hydraulic and fuel strainers, pharmaceutical and food sieving, and laboratory test work.

Plain, Twill or Dutch Weave at This Rating?

At this fineness, compare plain weave against twill (heavier wire, more durable) and dutch weave (higher strength, pressure-resistant, nominal rather than absolute rating) before finalizing the specification.

When to Step Up or Down from 200 Mesh

Move to 250 mesh when particles are passing that must be retained; drop back to 150 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Nickel Wire Mesh Does

Serving as electrodes, current collectors and caustic-resistant filter cloth in batteries, electrolyzers and alkaline chemical processes.

Fitting & Care

  • Degrease and handle with gloves before electrochemical use; contamination affects catalytic activity.
  • Spot-weld rather than solder tabs to keep contacts low-resistance.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
40-Mesh0.1800.45545551.0Nickel 200 (N02200)
60-Mesh0.1500.27327341.6Nickel 200 (N02200)
80-Mesh0.1200.19819838.7Nickel 200 (N02200)
100-Mesh0.1000.15415436.8Nickel 200 (N02200)
200-Mesh0.0500.0777736.8Nickel 201 (N02201)

Frequently Asked Questions

What is nickel wire mesh used for?

Mainly electrolyzer and battery electrodes, current collectors and filtration in hot caustic.

Nickel 200 or Nickel 201?

Use 201 for service above about 315 °C; 200 is fine below that.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.