Skip to content

Woven Wire Mesh · ISO 9044 / ASTM E2016

2 Mesh Plain Weave Wire Mesh Specifications

Specification data for 2 mesh plain weave wire mesh to ISO 9044 / ASTM E2016: aperture and micron rating, standard and alternative wire diameters, open area, weight per square metre, and the applications this fineness is commonly used for.

2 Mesh Specification Row (ISO 9044 / ASTM E2016)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Weight SS (kg/mu00b2)Reference standard
2-Mesh1.60011.1001110076.42.64ISO 9044

2 Mesh to Micron & Aperture

Openings per inch2
Aperture (opening width)11.1 mm
Micron rating11100 µm
Standard wire diameter1.6 mm
Open area76.4 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 2 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire2.080 mm10.620 mm10620 µm69.9 %4.46 kg/m²
Standard wire1.600 mm11.100 mm11100 µm76.4 %2.64 kg/m²
Fine wire1.200 mm11.500 mm11500 µm82.0 %1.48 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 2 Mesh

The standard 2 mesh weave presents an open area of about 76.4%. At this count the mesh presents little flow resistance; selection is normally driven by particle retention and mechanical strength rather than pressure drop.

2 Mesh Cloth Weight

Standard 2 mesh stainless cloth weighs approximately 2.64 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 2 Mesh Plain Weave Wire Mesh

2 mesh plain weave wire mesh is commonly specified for coarse screening and grading, safety guarding, animal enclosures, plaster and render reinforcement, and support layers behind finer filter cloth.

Plain, Twill or Dutch Weave at This Rating?

Plain square weave is the standard at this count: every opening is a true square of the stated aperture, retention is absolute for hard spherical particles, and the cloth is easy to clean.

When to Step Up or Down from 2 Mesh

Move to 4 mesh when particles are passing that must be retained. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 9044 / ASTM E2016)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Weight SS (kg/mu00b2)Reference standard
2-Mesh1.60011.1001110076.42.64ISO 9044
4-Mesh1.0005.350535071.02.06ISO 9044
8-Mesh0.8002.375237556.02.64ISO 9044
10-Mesh0.5501.990199061.41.56ISO 9044
20-Mesh0.4000.87087046.91.65ISO 9044
30-Mesh0.3000.54754741.71.39ISO 9044
40-Mesh0.2500.38538536.81.29ISO 9044
50-Mesh0.2200.28828832.11.25ISO 9044
60-Mesh0.1900.23323330.41.12ISO 9044
80-Mesh0.1400.17717831.30.81ISO 9044
100-Mesh0.1000.15415436.80.51ISO 9044
120-Mesh0.0900.12212233.00.50ISO 9044
150-Mesh0.0660.10310337.20.34ISO 9044
200-Mesh0.0530.0747434.00.29ISO 9044
250-Mesh0.0400.0626236.80.21ISO 9044
325-Mesh0.0360.0424229.10.22ISO 9044
400-Mesh0.0300.0343427.80.19ISO 9044
500-Mesh0.0250.0262625.80.16ISO 9044
635-Mesh0.0200.0202025.00.13ISO 9044

Frequently Asked Questions

What is the open area of 2 mesh?

With standard wire, 2 mesh presents about 76.4% open area. Open area falls as wire diameter rises; use the wire-options table on this page to compare.

What particle size will 2 mesh remove?

Hard, roughly spherical particles larger than about 11100 µm are retained. Fibrous or plate-like particles can pass an aperture larger than their smallest dimension, so validate with the real contaminant where retention is critical.

Is 2 mesh a screening or a filtration mesh?

2 mesh sits in the screening range — grading, guarding and support duties. True liquid filtration normally starts around 80–100 mesh and finer.

In which materials is 2 mesh plain weave wire mesh available?

Stainless 304 and 316/316L are standard; brass, phosphor bronze, copper, Monel, Inconel, Hastelloy, nickel and titanium are woven to order for special chemistry or temperature.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.