Skip to content

Woven Wire Mesh · ASTM E2016 / ISO 9044

150 Mesh Copper Wire Mesh Specifications

A roll of bright woven pure copper wire mesh partially unrolled on a light workbench, showing the fine square weave

The 150 mesh specification of copper wire mesh is defined by ASTM E2016 / ISO 9044. The tables below reproduce the standard row — wire diameter, aperture and open area — and convert the count to a micron rating for filtration selection. The technical drawing redraws to the values selected.

150 Mesh Specification Row (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
150-Mesh0.0660.10310337.2C11000 ETP copper

150 Mesh to Micron & Aperture

Openings per inch150
Aperture (opening width)0.103 mm
Micron rating103 µm
Standard wire diameter0.066 mm
Open area37.1 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 150 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.086 mm0.084 mm84 µm24.3 %0.57 kg/m²
Standard wire0.066 mm0.103 mm103 µm37.2 %0.34 kg/m²
Fine wire0.050 mm0.120 mm120 µm50.1 %0.19 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 150 Mesh

The standard 150 mesh weave presents an open area of about 37.1%. A common design rule is to keep the clean-mesh approach velocity low enough that initial pressure drop is negligible; the mesh then acts as the cake support.

150 Mesh Cloth Weight

Standard 150 mesh stainless cloth weighs approximately 0.34 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 150 Mesh Copper Wire Mesh

150 mesh copper wire mesh is commonly specified for liquid filtration and clarification, extruder screen packs, hydraulic and fuel strainers, pharmaceutical and food sieving, and laboratory test work.

Plain, Twill or Dutch Weave at This Rating?

Plain square weave is the standard at this count: every opening is a true square of the stated aperture, retention is absolute for hard spherical particles, and the cloth is easy to clean.

When to Step Up or Down from 150 Mesh

Move to 200 mesh when particles are passing that must be retained; drop back to 120 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Copper Wire Mesh Does

Conducting, shielding and screening with woven pure copper cloth — the go-to metal mesh for RF shielding, grounding grids, battery and electrochemical work and copper-specific screening.

Fitting & Care

  • Handle with gloves; skin oils start tarnish spots that raise contact resistance on shielding seams.
  • Bond seams by soldering or with conductive gasket — a mechanical overlap alone leaks RF.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
16-Mesh0.2801.308130867.6C11000 ETP copper
22-Mesh0.1151.040104081.0C11000 ETP copper
40-Mesh0.2500.38538536.8C11000 ETP copper
60-Mesh0.1100.31331355.0C11000 ETP copper
100-Mesh0.1100.14414432.0C11000 ETP copper
150-Mesh0.0660.10310337.2C11000 ETP copper

Frequently Asked Questions

What is copper wire mesh used for?

Mostly RF/EMI shielding and Faraday cages, grounding, electrochemistry and battery work, architectural screens and slug barriers.

Does copper mesh rust?

Copper does not rust; it tarnishes and forms a green-brown patina that protects the metal underneath.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.