Woven Wire Mesh · ASTM E2016 / ISO 9044

100 Mesh Copper Wire Mesh Specifications

A roll of bright woven pure copper wire mesh partially unrolled on a light workbench, showing the fine square weave

100 mesh denotes 100 wires per inch in each direction. For copper wire mesh the governing document is ASTM E2016 / ISO 9044; the specification row, aperture-micron conversion and selection guidance for this count follow.

100 Mesh Specification Row (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
100-Mesh0.1100.14414432.0C11000 ETP copper

100 Mesh to Micron & Aperture

Openings per inch100
Aperture (opening width)0.154 mm
Micron rating154 µm
Standard wire diameter0.1 mm
Open area36.7 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 100 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.130 mm0.124 mm124 µm23.8 %0.87 kg/m²
Standard wire0.100 mm0.154 mm154 µm36.8 %0.51 kg/m²
Fine wire0.075 mm0.179 mm179 µm49.7 %0.29 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 100 Mesh

The standard 100 mesh weave presents an open area of about 36.7%. A common design rule is to keep the clean-mesh approach velocity low enough that initial pressure drop is negligible; the mesh then acts as the cake support.

100 Mesh Cloth Weight

Standard 100 mesh stainless cloth weighs approximately 0.51 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 100 Mesh Copper Wire Mesh

100 mesh copper wire mesh is commonly specified for liquid filtration and clarification, extruder screen packs, hydraulic and fuel strainers, pharmaceutical and food sieving, and laboratory test work.

When to Step Up or Down from 100 Mesh

Move to 120 mesh when particles are passing that must be retained; drop back to 80 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Copper Wire Mesh Does

Conducting, shielding and screening with woven pure copper cloth — the go-to metal mesh for RF shielding, grounding grids, battery and electrochemical work and copper-specific screening.

Fitting & Care

  • Handle with gloves; skin oils start tarnish spots that raise contact resistance on shielding seams.
  • Bond seams by soldering or with conductive gasket — a mechanical overlap alone leaks RF.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ASTM E2016 / ISO 9044)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Alloy
16-Mesh0.2801.308130867.6C11000 ETP copper
22-Mesh0.1151.040104081.0C11000 ETP copper
40-Mesh0.2500.38538536.8C11000 ETP copper
60-Mesh0.1100.31331355.0C11000 ETP copper
100-Mesh0.1100.14414432.0C11000 ETP copper
150-Mesh0.0660.10310337.2C11000 ETP copper

Frequently Asked Questions

What is copper wire mesh used for?

Mostly RF/EMI shielding and Faraday cages, grounding, electrochemistry and battery work, architectural screens and slug barriers.

Does copper mesh rust?

Copper does not rust; it tarnishes and forms a green-brown patina that protects the metal underneath.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.