100 mesh denotes 100 wires per inch in each direction. For copper wire mesh the governing document is ASTM E2016 / ISO 9044; the specification row, aperture-micron conversion and selection guidance for this count follow.
100 Mesh Specification Row (ASTM E2016 / ISO 9044)
| Mesh count | Wire diameter (mm) | Aperture (mm) | Micron rating (u00b5m) | Open area (%) | Alloy |
|---|---|---|---|---|---|
| 100-Mesh | 0.110 | 0.144 | 144 | 32.0 | C11000 ETP copper |
100 Mesh to Micron & Aperture
| Openings per inch | 100 |
|---|---|
| Aperture (opening width) | 0.154 mm |
| Micron rating | 154 µm |
| Standard wire diameter | 0.1 mm |
| Open area | 36.7 % |
Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.
Wire Diameter Options at 100 Mesh
| Option | Wire dia | Aperture | Micron | Open area | Weight (SS) |
|---|---|---|---|---|---|
| Heavy wire | 0.130 mm | 0.124 mm | 124 µm | 23.8 % | 0.87 kg/m² |
| Standard wire | 0.100 mm | 0.154 mm | 154 µm | 36.8 % | 0.51 kg/m² |
| Fine wire | 0.075 mm | 0.179 mm | 179 µm | 49.7 % | 0.29 kg/m² |
Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.
Open Area & Flow at 100 Mesh
The standard 100 mesh weave presents an open area of about 36.7%. A common design rule is to keep the clean-mesh approach velocity low enough that initial pressure drop is negligible; the mesh then acts as the cake support.
100 Mesh Cloth Weight
Standard 100 mesh stainless cloth weighs approximately 0.51 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.
Typical Applications for 100 Mesh Copper Wire Mesh
100 mesh copper wire mesh is commonly specified for liquid filtration and clarification, extruder screen packs, hydraulic and fuel strainers, pharmaceutical and food sieving, and laboratory test work.
When to Step Up or Down from 100 Mesh
Move to 120 mesh when particles are passing that must be retained; drop back to 80 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.
What Copper Wire Mesh Does
Conducting, shielding and screening with woven pure copper cloth — the go-to metal mesh for RF shielding, grounding grids, battery and electrochemical work and copper-specific screening.
Fitting & Care
- Handle with gloves; skin oils start tarnish spots that raise contact resistance on shielding seams.
- Bond seams by soldering or with conductive gasket — a mechanical overlap alone leaks RF.