Skip to content

Laboratory & Medical Mesh · ASTM E11

ASTM E11 ASTM E11 Test Sieve (8 in / 12 in) Specifications

Several 8 inch ASTM E11 test sieves with brass and stainless frames stacked with a receiver pan, soil samples beside them

ASTM E11 Test Sieve (8 in / 12 in) is used for grading soils, aggregates, powders and granules by US standard sieve number in 8 in and 12 in frames built to ASTM E11. ASTM E11 is the reference cited for it on drawings, datasheets and purchase orders.

What ASTM E11 Means for ASTM E11 Test Sieve (8 in / 12 in)

The dimensions in the table below are supplied to suit ASTM E11. Where the standard sets requirements for the finished appliance, device or system, compliance testing of that assembly stays with its manufacturer; we supply the metal mesh part to the drawing and can provide material certificates and dimensional reports with the shipment.

Equivalent Standards

ASTM E11 is the US test-sieve aperture series corresponding to ISO 565 / ISO 3310-1.

ASTM E11 Test Sieve (8 in / 12 in) Dimensions

US sieve No.Frame diameter (mm)Frame height (mm)Aperture (mm)Wire diameter (mm)Frame
No. 4203504.7501.600SS304 full height
No. 10203502.0000.900SS304 full height
No. 40203500.4250.280SS304 full height
No. 100203500.1500.100SS304 full height
No. 200203250.0750.050Brass half height
No. 200 u00b7 12 in305750.0750.050SS304 full height

Specifying ASTM E11 Test Sieve (8 in / 12 in) Beyond the Standard

  • Sieve number: Order by US sieve No. (No. 4 = 4.75 mm, No. 200 = 75 µm) as named in the test method.
  • Frame height: Full height (2 in) for most work; half height (1 in) to fit more sieves on a shaker.
  • Frame material: Stainless for wet washing and durability; brass for traditional dry sieving.

When ASTM E11 Test Sieve (8 in / 12 in) Is Not the Right Choice

Not for wet-sieving heavy slurries unless the sieve is a wet-wash design with a deep frame.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ASTM E11)

US sieve No.Frame diameter (mm)Frame height (mm)Aperture (mm)Wire diameter (mm)Frame
No. 4203504.7501.600SS304 full height
No. 10203502.0000.900SS304 full height
No. 40203500.4250.280SS304 full height
No. 100203500.1500.100SS304 full height
No. 200203250.0750.050Brass half height
No. 200 u00b7 12 in305750.0750.050SS304 full height

Frequently Asked Questions

When should I use a 12 in test sieve?

For larger samples, such as coarse aggregate, where an 8 in sieve would be overloaded.

What is the aperture of a No. 200 sieve?

75 µm (0.075 mm).

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.