Skip to content

Kitchen & Appliance Filters · IEC 60456 / IEC 61121

60 Mesh Washing Machine & Dryer Lint Filter Mesh Specifications

A rectangular stainless steel woven lint filter screen in a white plastic frame, partly covered with grey lint

This page covers the 60 mesh count of washing machine & dryer lint filter mesh: the woven specification per IEC 60456 / IEC 61121, the particle size it retains, the open area it presents to flow, and the neighbouring counts to step to when the separation requires it.

60 Mesh Specification Row (IEC 60456 / IEC 61121)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
60-Mesh0.1900.23323330.4SS304

60 Mesh to Micron & Aperture

Openings per inch60
Aperture (opening width)0.23 mm
Micron rating233 µm
Standard wire diameter0.19 mm
Open area30.4 %

Aperture = (25.4 mm ÷ mesh count) − wire diameter. The micron rating equals the aperture in micrometres; actual retention also depends on particle shape and cake formation.

Wire Diameter Options at 60 Mesh

OptionWire diaApertureMicronOpen areaWeight (SS)
Heavy wire0.247 mm0.176 mm176 µm17.4 %1.88 kg/m²
Standard wire0.190 mm0.233 mm233 µm30.4 %1.12 kg/m²
Fine wire0.143 mm0.281 mm281 µm44.0 %0.63 kg/m²

Heavier wire adds strength and abrasion life but closes the aperture; finer wire opens the aperture and raises throughput at the cost of durability. Specify mesh count AND wire diameter to fix the aperture unambiguously.

Open Area & Flow at 60 Mesh

The standard 60 mesh weave presents an open area of about 30.4%. At this count the mesh presents little flow resistance; selection is normally driven by particle retention and mechanical strength rather than pressure drop.

60 Mesh Cloth Weight

Standard 60 mesh stainless cloth weighs approximately 1.12 kg/m² (density 7.93 g/cm³ basis; brass and copper weave roughly 10% heavier, aluminum about one third). Use this figure for roll handling and freight estimation.

Typical Applications for 60 Mesh Washing Machine & Dryer Lint Filter Mesh

60 mesh washing machine & dryer lint filter mesh is commonly specified for general straining and sieving, paint and coating filtration, grease filters, insect screening, grain cleaning and pre-filtration ahead of fine media.

Plain, Twill or Dutch Weave at This Rating?

Plain square weave is the standard at this count: every opening is a true square of the stated aperture, retention is absolute for hard spherical particles, and the cloth is easy to clean.

When to Step Up or Down from 60 Mesh

Move to 80 mesh when particles are passing that must be retained; drop back to 50 mesh when the element blinds too quickly or the pressure drop is excessive. In a multi-layer pack, pair this count with a coarser support mesh downstream to carry the pressure load.

What Washing Machine & Dryer Lint Filter Mesh Does

Trapping lint and fibers in washing machines and tumble dryers before they reach the pump, drain or heater.

Fitting & Care

  • Clean dryer lint screens after every load.
  • Wash the screen with water and a brush monthly to remove softener film.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (IEC 60456 / IEC 61121)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
40-Mesh0.2500.38538536.8SS304
60-Mesh0.1900.23323330.4SS304
80-Mesh0.1400.17717831.3SS304
100-Mesh0.1000.15415436.8SS304

Frequently Asked Questions

What mesh is used for dryer lint screens?

Usually 60–100 mesh, balancing lint capture and airflow.

Why does my dryer take longer?

A blinded lint screen — fabric softener film can block it even when lint is removed.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.