Skip to content

Sintered Mesh · ISO 4022

304 Stainless Steel Sintered Fiber Felt

304 Stainless Steel sintered fiber felt is stocked to ISO 4022. The alloy provides good general corrosion resistance in atmosphere and fresh water and is essentially non-magnetic (annealed); the practical service limit is approx. +450 °C continuous. Property data, alloy comparison and the specification table follow.

Why Choose 304 Stainless Steel for Sintered Fiber Felt

The standard general-purpose stainless mesh alloy. For sintered fiber felt, this matters when good general corrosion resistance in atmosphere and fresh water is the controlling requirement.

Alloy Properties

Grade designationAISI 304 (1.4301)
Magnetic responseEssentially non-magnetic (annealed)
Service temperatureapprox. +450 °C continuous
Corrosion characteristicGood general corrosion resistance in atmosphere and fresh water

Corrosion Behavior in Filtration Service

304 gives good resistance to atmospheric exposure, fresh water and most neutral media, and is the standard general-purpose grade for sintered fiber felt. In chloride-bearing service (seawater, brines, road-salt spray) step up to 316L; in reducing acids consider a nickel alloy.

Cleaning & Compatibility

Stainless sintered fiber felt can be cleaned by backflush, ultrasonic bath, steam and most CIP chemistry. Two cautions: (1) avoid extended contact with hydrochloric acid or hypochlorite sanitizers, which pit even 316; (2) where the mesh contacts carbon steel during fabrication or service, iron pick-up can rust-stain the surface — specify passivation after fabrication.

Specifications of Sintered Fiber Felt Available in 304 Stainless Steel

Micron rating (u00b5m)Thickness (mm)Porosity (%)FormReference standard
30.3575Sheet / cut discISO 4022
50.4078Sheet / cut discISO 4022
100.4580Sheet / cut discISO 4022
200.5582Sheet / cut discISO 4022
400.6083Sheet / cut discISO 4022
600.7085Sheet / cut discISO 4022

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ISO 4022)

Micron rating (u00b5m)Thickness (mm)Porosity (%)FormReference standard
30.3575Sheet / cut discISO 4022
50.4078Sheet / cut discISO 4022
100.4580Sheet / cut discISO 4022
200.5582Sheet / cut discISO 4022
400.6083Sheet / cut discISO 4022
600.7085Sheet / cut discISO 4022

Frequently Asked Questions

Can 304 Stainless Steel sintered fiber felt be welded into frames?

Yes — spot, TIG and plasma welding are standard for framing and edging. Use matching filler, keep heat input low to protect the fine wires, and re-passivate stainless after fabrication.

Is 304 Stainless Steel sintered fiber felt magnetic?

304 Stainless Steel sintered fiber felt is essentially non-magnetic (annealed). Note that heavy cold-working during weaving can make austenitic stainless slightly magnetic at the wire surface.

What corrosion resistance does 304 Stainless Steel offer?

304 Stainless Steel provides good general corrosion resistance in atmosphere and fresh water, with a practical service range of approx. +450 °C continuous.

What temperature can 304 Stainless Steel sintered fiber felt run at?

The practical continuous service limit is approx. +450 °C continuous. Above it, oxidation scales the wire surface and the aperture drifts; for hotter duty move up the alloy ladder (Inconel, and sintered constructions for mechanical stability).

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.