Soffit, Vent & Weep Hole Insect Screen is used for screening attic soffit vents, foundation vents and brick weep holes against insects, rodents and wind-blown embers while keeping ventilation open. IRC R806 ventilation is the reference cited for it on drawings, datasheets and purchase orders.

What IRC R806 ventilation Means for Soffit, Vent & Weep Hole Insect Screen

The dimensions in the table below are supplied to suit IRC R806 ventilation. Where the standard sets requirements for the finished appliance, device or system, compliance testing of that assembly stays with its manufacturer; we supply the metal mesh part to the drawing and can provide material certificates and dimensional reports with the shipment.

Soffit, Vent & Weep Hole Insect Screen Dimensions

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
16-Mesh0.2801.308130867.0Aluminum
18-Mesh0.2801.131113164.0SS304
1/8 in ember mesh0.5003.175317574.0SS304 (WUI ember-resistant)

Specifying Soffit, Vent & Weep Hole Insect Screen Beyond the Standard

  • Opening: 16–18 mesh for insects; 1/8 in (3.2 mm) for ember resistance per local code.
  • Free area: Increase the vent size to compensate for the screen's reduced open area.
  • Material: SS304 in coastal or ember zones; aluminum indoors.

When Soffit, Vent & Weep Hole Insect Screen Is Not the Right Choice

Not a rodent barrier for large openings without heavier welded mesh.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (ICC-ES / IRC R806 ventilation)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
16-Mesh0.2801.308130867.0Aluminum
18-Mesh0.2801.131113164.0SS304
1/8 in ember mesh0.5003.175317574.0SS304 (WUI ember-resistant)