Skip to content

Acoustic & Electronics Mesh · MIL-DTL-83528 / IEEE 299

22 Mesh EMI / RFI Shielding Mesh Specifications

A roll of fine copper woven EMI shielding mesh partially unrolled on an electronics bench

22 mesh emi / rfi shielding mesh has 22 openings per linear inch. Woven to MIL-DTL-83528 / IEEE 299, this page lists the controlling specification — wire diameter, aperture, micron rating, open area and cloth weight — together with the wire options available at this count and the duties it is normally specified for.

22 Mesh Specification Row (MIL-DTL-83528 / IEEE 299)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialShielding @ 1 GHz (dB)
22-Mesh0.1151.04081Copper50

Typical Applications for 22 Mesh EMI / RFI Shielding Mesh

22 mesh emi / rfi shielding mesh is commonly specified for general straining and sieving, paint and coating filtration, grease filters, insect screening, grain cleaning and pre-filtration ahead of fine media.

What EMI / RFI Shielding Mesh Does

Attenuating electromagnetic and radio-frequency interference through vents, windows and enclosures while still passing air and light.

Fitting & Care

  • Clamp the mesh edges under a conductive gasket or solder them continuously to the frame.
  • Keep paint and anodizing off contact faces; mask them before finishing.
Mesh count to micron conversion chart
Mesh count to aperture and micron rating. Confirm the exact figure against the specification table below — wire diameter, not mesh count alone, sets the aperture.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (MIL-DTL-83528 / IEEE 299)

Mesh countWire diameter (mm)Aperture (mm)Open area (%)MaterialShielding @ 1 GHz (dB)
22-Mesh0.1151.04081Copper50
60-Mesh0.1100.31355Copper65
100-Mesh0.1100.14432Phosphor bronze75
100-Mesh Monel0.1100.14432Monel 40075
145-Mesh0.0560.11946SS30470

Frequently Asked Questions

Which mesh is best for EMI shielding?

Copper or phosphor bronze in 60–100 mesh is common; Monel or stainless are chosen where corrosion is a concern.

How much shielding does woven mesh give?

Typically 50–75 dB around 1 GHz, depending on mesh count, wire and the quality of the edge bond.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.