Skip to content

Home, HVAC & Safety Mesh · NFPA 211 / IRC R1003.9

316L Stainless Steel Chimney Cap & Fireplace Spark Arrester Screen

A stainless steel chimney cap with a woven wire spark arrester screen around its sides mounted on top of a brick chimney

Chimney Cap & Fireplace Spark Arrester Screen in 316L Stainless Steel (AISI 316L (1.4404)) is used for stopping burning embers from leaving the chimney and keeping birds and animals out, while letting flue gas draw freely. The alloy gives superior resistance, including chlorides, brines, food CIP and mild acids and is essentially non-magnetic, with a practical service limit of approx. +550 °C continuous.

Alloy Properties

Grade designationAISI 316L (1.4404)
Magnetic responseEssentially non-magnetic
Service temperatureapprox. +550 °C continuous
Corrosion characteristicSuperior resistance, including chlorides, brines, food CIP and mild acids

Specifications of Chimney Cap & Fireplace Spark Arrester Screen Available in 316L Stainless Steel

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
2-Mesh1.20011.5001150082.4SS304
3-Mesh1.0007.470747077.8SS304
4-Mesh0.8005.550555076.4SS304 / galvanized

Where 316L Stainless Steel Chimney Cap & Fireplace Spark Arrester Screen Is Used

  • Chimney sweeps & installers: spark screens fitted to new and existing chimney caps.
  • Wildfire-prone regions: mandatory spark arresters on wood-burning chimneys.
  • Stove & fireplace makers: screens supplied with cap kits.
  • Outdoor fire pits & pizza ovens: spark screens on flues and lids.

Ordering Chimney Cap & Fireplace Spark Arrester Screen in 316L Stainless Steel

  • Opening size: Many codes require openings no larger than 1/2 in (12.7 mm) and no smaller than 3/8 in so the screen does not clog with soot.
  • Wire & alloy: SS304 or SS316 heavy wire survives flue heat and creosote; galvanized corrodes quickly.
  • Screen area: Free area of the screen should be at least four times the flue area so draft is not restricted.

Mistakes to Avoid with Chimney Cap & Fireplace Spark Arrester Screen

  • Choosing insect-fine mesh, which blocks with soot and causes smoke spillage indoors.
  • Using galvanized screen on a wood stove, which scales and fails within a few seasons.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Adjust the parameters in the drawing above and click "Request this configuration" to send the exact specification straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (NFPA 211 / IRC R1003.9)

Mesh countWire diameter (mm)Aperture (mm)Micron rating (u00b5m)Open area (%)Material
2-Mesh1.20011.5001150082.4SS304
3-Mesh1.0007.470747077.8SS304
4-Mesh0.8005.550555076.4SS304 / galvanized

Frequently Asked Questions

Is a spark arrester required on my chimney?

Many jurisdictions require one, especially in wildfire areas; check the local fire code.

Why is smoke coming back into the room?

A soot-blocked spark screen is a common cause; clean it and check the opening size.

How do I request a quotation?

Use the technical drawing on this page to pick the exact specification, then submit it with the quote form. We respond within one business day.