Material page for welded wire mesh panels in Pure Copper. The EMI/RFI shielding and Faraday-cage mesh material. Covers the grade designation (C11000), corrosion and magnetic behavior, cleaning and compatibility notes, and the specifications available.
Why Choose Pure Copper for Welded Wire Mesh Panels
The EMI/RFI shielding and Faraday-cage mesh material. For welded wire mesh panels, this matters when good atmospheric resistance with a stable patina; outstanding conductivity is the controlling requirement.
Alloy Properties
| Grade designation | C11000 |
|---|---|
| Magnetic response | Non-magnetic |
| Service temperature | approx. +200 °C |
| Corrosion characteristic | Good atmospheric resistance with a stable patina; outstanding conductivity |
Corrosion Behavior in Filtration Service
Copper and brass welded wire mesh panels resist atmospheric corrosion and fresh water well, tarnishing to a stable patina. Avoid ammonia and ammonium compounds (stress-corrosion cracking of brass) and strong oxidizing acids. In marine service, phosphor bronze outperforms plain brass.
Comparable Alloys
Within the copper family: brass for economy and appearance, phosphor bronze for fatigue strength and marine air, pure copper where conductivity (EMI shielding) is the point. For structural filtration duties, stainless 304/316 is the usual alternative.
Specifications of Welded Wire Mesh Panels Available in Pure Copper
| Opening (mm) | Wire diameter (mm) | Format | Standard size | Reference standard |
|---|---|---|---|---|
| 12.7x12.7 | 1.6 | Panel / roll | 1.0 x 2.0 m | EN 10223-7 |
| 25.4x25.4 | 2.0 | Panel / roll | 1.0 x 2.0 m | EN 10223-7 |
| 50.8x50.8 | 2.5 | Panel | 1.2 x 2.4 m | EN 10223-7 |
| 50x50 | 4.0 | Panel | 2.0 x 3.0 m | EN 10223-7 |
| 75x75 | 5.0 | Panel | 2.0 x 3.0 m | EN 10223-7 |
| 100x100 | 6.0 | Panel | 2.0 x 6.0 m | EN 10223-7 |