Skip to content

Home, HVAC & Safety Mesh · AMCA 500-L / ASHRAE 62.1 · Application guide

What Is Hydrophobic Mesh Moisture-Eliminator Air Filter Used For?

A rectangular knitted stainless steel mesh moisture eliminator filter panel installed in a rooftop air intake louver

Hydrophobic Mesh Moisture-Eliminator Air Filter is selected when an assembly or process calls for stripping rain and mist droplets out of outdoor air intakes so water does not soak downstream filters, coils and ductwork. This application guide to the AMCA 500-L / ASHRAE 62.1 type covers concrete end-uses, the specification checklist, correct installation, and where an alternative mesh or filter medium performs better.

Typical Applications for Hydrophobic Mesh Moisture-Eliminator Air Filter

Where Hydrophobic Mesh Moisture-Eliminator Air Filter is specified and bought:

  • Rooftop units & AHUs: fresh-air intake moisture eliminators.
  • Marine & offshore HVAC: salt-mist removal on ships and platforms.
  • Generator & turbine rooms: air-intake protection.
  • Data centers: outside-air economizer intakes.

How to Specify Hydrophobic Mesh Moisture-Eliminator Air Filter for Your Application

  • Face velocity: Keep below about 3 m/s or droplets re-entrain.
  • Media: Knitted SS304/316 layered with polypropylene for droplet capture.
  • Drainage: Provide a drain path at the bottom of the frame.
  • Standard: Quote AMCA 500-L / ASHRAE 62.1 and the size designation from the table on the product page, plus any value you changed in the technical drawing.

Handling & Installation Practice

  • Install upstream of particulate filters, with a drip tray below.
  • Rinse off salt and dirt deposits periodically.

Common Selection Mistakes with Hydrophobic Mesh Moisture-Eliminator Air Filter

  • Running above the rated face velocity, which carries water through.
  • Leaving no drain path so water pools in the frame.

Where Hydrophobic Mesh Moisture-Eliminator Air Filter Is Not the Right Choice

Not a particulate filter — fit standard filters downstream.

If This Construction Is Not the Right Fit

Closely related mesh types for the same duty — compare open area, aperture range and cleanability before you commit.

Technical Drawing

Customize the parameters below — every spec field is editable, and the drawing redraws to match the values you choose. Changing the size will snap the other fields to that size's standard values; you can then override any individual value.

Sends the selected values to the quote form below.

Request a Quote

Set the size and options in the drawing above, then send the exact configuration straight to this form.

Request a Quotation

Specification
Business Information

Dimensions & Specifications (AMCA 500-L / ASHRAE 62.1)

SizeWidth (mm)Height (mm)Thickness (mm)MediaMax face velocity (m/s)
24 u00d7 24 u00d7 2 in61061050Knitted SS304 + PP layers3.0
24 u00d7 12 u00d7 2 in61030550Knitted SS304 + PP layers3.0
24 u00d7 24 u00d7 4 in610610100Knitted SS316 multi-layer3.5

Frequently Asked Questions

What is Hydrophobic Mesh Moisture-Eliminator Air Filter used for?

Stripping rain and mist droplets out of outdoor air intakes so water does not soak downstream filters, coils and ductwork.

What is a moisture eliminator filter?

A knitted mesh pad that captures droplets and drains them away.

What face velocity should a moisture eliminator run at?

Below about 3 m/s.

Which alloy for salt air?

SS316 knitted mesh.

Can I get a quote for Hydrophobic Mesh Moisture-Eliminator Air Filter to my own drawing?

Yes. Set the size and any custom value in the technical drawing on the product page and send it with the quote form; we reply within one business day.